PHYSICAL PROPERTIES
|
|
Method
|
Description
|
Value
|
|
ASTM D 1622
|
Density
|
0.45-0.5 lb/ft3
|
|
ASTM C 518
|
Thermal
resistence 2 days @ 76°F
Thermal resistence 90 days @ 76°F
|
3.81 ft 2h
°f/BTU.in
3.81 ft 2h °f/BTU.in
|
|
ASTM E 283-91
|
Air Leakage @
75 Pa (25 miles/hr wind)
|
0.00013 ft3/s.ft2
|
|
Sustained wind
load for 60 minutes @ 1000 Pa (90 miles/hr wind)
|
No damage
|
|
Gust wind load
test @ 3000 Pa (160 miles/hr wind)
|
No damage
|
|
ASTM D 1621
|
Compressive
strength
|
0.7psi
|
|
ASTM D 1623
|
Tensile strength
|
2.5psi
|
|
ASTM E 413-87
ASTM C 423
|
Sound
Transmission Class (STC)
Noise Reduction Coefficient (NRC)
|
39
75
|
|
ASTM E 96
|
Water Vapor
Permeance (Dry cup)
|
5.47 Perms
|
|
CGSB 51.23-92
|
Off Gassing
Tests (VOC Emissions)
|
Pass (Not toxic
vapors)
|
|
ASTM E 84
|
Surface Burning
Characteristics (6")
-
Flame Spread
Index
- Smoke Developmen
|
21 Class 1
216
|
|
| We request that
customers inspect and test our product before use and satisfy
themselves as to contents and suitability. Nothing herein shall
constitute a warranty, expressed or implied, including any warranty for
merchantability or fitness, nor is protection from any law or patent
inferred. All rights are reserved. The foam product is combustible and
must be covered by an approved thermal barrier. The exclusive remedy
for all proven claims is replacement of our materials.
|
|
 |
Using
products with the EnergyStar label
can save energy.
Saving
energy reduces and lowers ultility bills.
|

|
4637
Route 145,
Durham, New York 12422 Phone:
518-239-8945 E-mail: info@twinsulation.com
|
Privacy
Policy | User Agreement
© Copyright 2004-2012 Twinsulation, Inc. All Rights Reserved. Site by Apogee

|